{"id":2105,"date":"2025-10-21T02:51:19","date_gmt":"2025-10-21T02:51:19","guid":{"rendered":"https:\/\/www.ktechsolar.com\/?post_type=case&#038;p=2105"},"modified":"2025-10-21T02:54:24","modified_gmt":"2025-10-21T02:54:24","slug":"two-5-5kw-inverters-two-10kwh-batteries-build-a-household-off-grid-energy-storage-system","status":"publish","type":"case","link":"https:\/\/www.ktechsolar.com\/es\/case\/two-5-5kw-inverters-two-10kwh-batteries-build-a-household-off-grid-energy-storage-system\/","title":{"rendered":"Dos inversores de 5,5 kW + dos bater\u00edas de 10 kWh construyen un sistema dom\u00e9stico de almacenamiento de energ\u00eda sin conexi\u00f3n a la red el\u00e9ctrica"},"content":{"rendered":"<p><strong>[Antecedentes del cliente]<\/strong><\/p>\n<p>Apagones frecuentes, dependencia m\u00e9dica, facturas de electricidad elevadas<\/p>\n<p>En una ciudad con grandes oscilaciones t\u00e9rmicas entre el d\u00eda y la noche, una familia de cinco miembros sufr\u00eda frecuentes cortes de electricidad. Dos ni\u00f1os ten\u00edan que estudiar por la noche, un anciano depend\u00eda de equipos m\u00e9dicos y los aparatos de alta potencia, como aires acondicionados y calentadores de agua, generaban picos de demanda de electricidad por las tardes. Antes, la familia recurr\u00eda a generadores di\u00e9sel como fuente de energ\u00eda de reserva, pero \u00e9stos provocaban contaminaci\u00f3n ac\u00fastica, elevados costes de combustible y problemas de mantenimiento.<\/p>\n<p>Los requisitos b\u00e1sicos estaban claros: el sistema deb\u00eda almacenar suficiente energ\u00eda durante el d\u00eda para garantizar m\u00e1s de 6 horas de funcionamiento nocturno con alta carga, con una gesti\u00f3n totalmente automatizada para minimizar la intervenci\u00f3n manual.<\/p>\n<p><strong>[Ktech Energy Solution]<\/strong><\/p>\n<p>Ktech Energy dise\u00f1\u00f3 un sistema de almacenamiento solar \u201cde doble inversor y doble almacenamiento\u201d con despacho inteligente d\u00eda-noche y conmutaci\u00f3n en modo dual (almacenamiento\/conectado a la red) para hacer frente a los retos energ\u00e9ticos nocturnos:<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-2106 aligncenter\" src=\"https:\/\/www.ktechsolar.com\/wp-content\/uploads\/2025\/10\/1-575538.webp\" alt=\"\" width=\"800\" height=\"600\" srcset=\"https:\/\/www.ktechsolar.com\/wp-content\/uploads\/2025\/10\/1-575538.webp 800w, https:\/\/www.ktechsolar.com\/wp-content\/uploads\/2025\/10\/1-575538-768x576.webp 768w, https:\/\/www.ktechsolar.com\/wp-content\/uploads\/2025\/10\/1-575538-16x12.webp 16w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Propuesta de configuraci\u00f3n de productos Ktech<\/p>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr class=\"firstRow\" style=\"height: 18px;\">\n<td style=\"padding: 0px 7px; border-width: 1px; border-color: #000000;\" colspan=\"5\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Soluci\u00f3n ESS<\/td>\n<\/tr>\n<tr style=\"height: 18px;\">\n<td style=\"padding: 0 7px; border-left-width: 1px; border-left-color: #000000; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">No.<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top-width: 1px; border-top-color: #000000; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Equipamiento<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top-width: 1px; border-top-color: #000000; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Modo<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top-width: 1px; border-top-color: #000000; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Cantidad<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top-width: 1px; border-top-color: #000000; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Configuraci\u00f3n Justificaci\u00f3n<\/td>\n<\/tr>\n<tr style=\"height: 131px;\">\n<td style=\"padding: 0 7px; border-left-width: 1px; border-left-color: #000000; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">1<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Panel solar<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">550W<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">20<\/td>\n<td style=\"padding: 0px 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" width=\"268\">Dos inversores h\u00edbridos paralelos Ktech de 5,5 kW (11 kW pico) permiten el arranque simult\u00e1neo de CA y calentadores de agua. El modo sin conexi\u00f3n a la red logra una eficiencia &gt;98% para una tensi\u00f3n estable.<\/td>\n<\/tr>\n<tr style=\"height: 131px;\">\n<td style=\"padding: 0 7px; border-left-width: 1px; border-left-color: #000000; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">2<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Inversor<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">KE-5K5L1EF<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">2<\/td>\n<td style=\"padding: 0px 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" width=\"268\">Dos paquetes de bater\u00edas de litio Ktech NP-WG10 (10kWh cada uno, 20kWh en total), 90% de profundidad de descarga (DoD), suministran 5kW de potencia durante 6 horas, cubriendo la iluminaci\u00f3n nocturna, los dispositivos m\u00e9dicos y 3 ACs.<\/td>\n<\/tr>\n<tr style=\"height: 151px;\">\n<td style=\"padding: 0 7px; border-left-width: 1px; border-left-color: #000000; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">3<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">Bater\u00eda<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">ESS NP-WG10<\/td>\n<td style=\"padding: 0 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" nowrap=\"nowrap\">2<\/td>\n<td style=\"padding: 0px 7px; border-left: none; border-right-width: 1px; border-right-color: #000000; border-top: none; border-bottom-width: 1px; border-bottom-color: #000000;\" align=\"center\" valign=\"middle\" width=\"268\">20\u00d7550W de paneles solares monocristalinos (11kW en total), que generan ~55kWh diarios (5h de luz solar efectiva). La energ\u00eda sobrante carga primero las bater\u00edas y luego alimenta directamente los electrodom\u00e9sticos.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>[Filosof\u00eda del dise\u00f1o]<\/strong><\/p>\n<p>Asignaci\u00f3n din\u00e1mica + ahorro inteligente de energ\u00eda: Autonom\u00eda de 8 horas en d\u00edas nublados, automatizaci\u00f3n de la plataforma en la nube<\/p>\n<p>El sistema sigue la l\u00f3gica de \u201calmacenar de d\u00eda, utilizar de noche\u201d. La energ\u00eda solar carga las bater\u00edas por la ma\u00f1ana. Al mediod\u00eda, cuando las bater\u00edas est\u00e1n llenas, la energ\u00eda sobrante vuelve a la red para generar ingresos. Al atardecer, el sistema cambia sin problemas a la energ\u00eda de las bater\u00edas, con inversores que equilibran din\u00e1micamente la producci\u00f3n entre los paquetes de bater\u00edas dobles para evitar sobrecargas. Cuando el tiempo est\u00e1 nublado, la plataforma en la nube activa el \u201cModo Inteligente de Ahorro de Energ\u00eda\u201d, suspendiendo las cargas no esenciales para prolongar el tiempo de funcionamiento m\u00e1s all\u00e1 de las 8 horas.<\/p>\n<p><strong>[Comentarios de los clientes]<\/strong><\/p>\n<p>\u201cSe acabaron las preocupaciones por la electricidad nocturna, las facturas cayeron en picado y el ruido de los generadores di\u00e9sel es historia\u201d.\u201d<\/p>\n<p>El cliente qued\u00f3 impresionado: \u201cAntes racion\u00e1bamos el uso del aire acondicionado por la noche. Ahora, los ni\u00f1os estudian hasta tarde sin miedo a los apagones\u201d. La aplicaci\u00f3n muestra los niveles de bater\u00eda en tiempo real y nos permite priorizar los dispositivos m\u00e9dicos: una tranquilidad total\". Tras la instalaci\u00f3n, los costes mensuales de electricidad se redujeron dr\u00e1sticamente y el sistema casi silencioso elimin\u00f3 el ruido del generador di\u00e9sel.<\/p>","protected":false},"excerpt":{"rendered":"<p>[Antecedentes del cliente]<br \/>\nApagones frecuentes, dependencia m\u00e9dica, facturas de electricidad elevadas<\/p>\n<p>En una ciudad con grandes oscilaciones t\u00e9rmicas entre el d\u00eda y la noche, una familia de cinco miembros sufr\u00eda frecuentes cortes de electricidad. Dos ni\u00f1os ten\u00edan que estudiar por la noche, un anciano depend\u00eda de equipos m\u00e9dicos y los aparatos de alta potencia, como aires acondicionados y calentadores de agua, generaban picos de demanda de electricidad por las tardes.<\/p>","protected":false},"featured_media":2107,"template":"","case-category":[18],"case-tag":[],"class_list":["post-2105","case","type-case","status-publish","has-post-thumbnail","hentry","case-category-home-photovoltaic-energy-storage-solution"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.ktechsolar.com\/es\/wp-json\/wp\/v2\/case\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ktechsolar.com\/es\/wp-json\/wp\/v2\/case"}],"about":[{"href":"https:\/\/www.ktechsolar.com\/es\/wp-json\/wp\/v2\/types\/case"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ktechsolar.com\/es\/wp-json\/wp\/v2\/media\/2107"}],"wp:attachment":[{"href":"https:\/\/www.ktechsolar.com\/es\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"case-category","embeddable":true,"href":"https:\/\/www.ktechsolar.com\/es\/wp-json\/wp\/v2\/case-category?post=2105"},{"taxonomy":"case-tag","embeddable":true,"href":"https:\/\/www.ktechsolar.com\/es\/wp-json\/wp\/v2\/case-tag?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}