Kayis Series

AC-Coupled Inverter 3-6kW Single Phase

CAN-3KD5LETN CAN-3K/3K6/5K/6KD5LIEN

Features

Features
  • 01

    Easy energy storage upgrade for existing PV systems

  • 02

    Retain original on-grid inverter to reduce renovation costs

  • 03

    Compatible with multi-brand inverters, suitable for more application scenarios

  • 04

    Intelligently dispatch PV, batteries and loads to improve self-consumption rate

  • 05

    Support backup power operation and enhance household power supply reliability

  • 06

    Ideal energy storage upgrade solution for users with existing photovoltaic installations

Model CAN-3KD5LETN CAN-3KD5LIEN CAN-3K6D5LIEN CAN-5KD5LIEN CAN-6KD5LIEN
Uninterruptible Power Supply (UPS)
Rated Output Power (W) 3000 3000 3600 5000 6000
Rated Output Current (A) 13.7 13.7 16.4 22.8 27.3
Max.Output Current (A) 15 15 18 25 30
Peak Power (W) 2 Times Of Rated Power, 10s
Rated Voltage (V) 220/230, 0.88Un – U 1.1Un
Frequency (Hz) 50/45-55, 60/55-65
Total Voltage Harmonic Distortion (THDv) <3% (Rated power)
DC Current Output <0.5% X Rated current
Transfer Time (Bypass to Inverter) (ms) 10
Max.Number of Parallel Units 10
Battery Parameters
Battery Type Lead-acid or Lithium Iron Phosphate Battery
Max. Charge Current (Adjustable) (A) 125 62.5 75 105 125
Max. Discharge Current (A) 125 62.5 75 105 125
Rated Battery Voltage (V) 24 24 48 48 48
Charging Voltage Range (V) 20-30 20-30 40-60 40-60 40-60
Support Forced Battery Wake-up from Grid (Yes/No) Yes
Grid
Rated AC Voltage (V) 220 / 230
Rated AC Frequency (Hz) 50 / 60
Rated AC Output Current (A) 13.7 13.7 16.4 22.8 27.3
Rated AC Output Power (W) 3000 3000 3600 5000 6000
Power Factor (PF) 0.8 leading – 0.8 lagging
Total Current Harmonic Distortion (THDi) <3%
Bypass Overload Current (A) 45
Efficiency
Max.Efficiency 97.6%
Max.Charge/Discharge Efficiency 94.5%
Device Protection
Integrated Protection Over-temperature protection, overload protection, short-circuit protection, battery over-voltage protection, Leakage protection, anti-islanding protection, ground fault detection, surge protection, GFCI
Surge Protection Level AC Type III
General
Ingress Protection (IP) Rating IP66
Operating Temperature Range -40-60℃ (>45℃ Derating)
Humidity Range 0-100%RH (Non-condensing)
Noise Level @ 1m <45dB @ 25℃ (77°F)
Type of Cooling Intelligent Air Cooling
Communication Port RS485/CAN; Option 1: WiFi + Bluetooth, Option 2: 4G + Bluetooth
Dimensions(H×W×D) (mm) 493x400x150 (Excluding Connectors and Brackets)
Weight (kg) 20
Operating Altitude (m) <2000
Warranty
Warranty 5 Years / 10 Years
AC Connector Yes
Certification
Overview CE-LVD EN IEC 62109-1/-2,CE-EMC EN IEC 61000-6-1/-3, RoHS, VDE IEC 62920 , EN 50549