Kayis Series

Hybrid Inverter 6-12kW Three Phase American Grid

KE-6K/7K/7K5/8K/10K/12KD5L3UN

Features

Features
  • 01

    The AC-DC matching ratio can reach 2 times

  • 02

    MPPT tracking efficiency up to 99%

  • 03

    Supports lead-acid / lithium battery connection

  • 04

    Supports multiple communication interfaces

  • 05

    Compatible with AFCI, GFCI and RSD functions

  • 06

    Ingress Protection (IP) Rating: IP66

Model KE-6KD5L3UN KE-7KD5L3UN KE-7K5D5L3UN KE-8KD5L3UN KE-10KD5L3UN KE-12KD5L3UN
Battery Input Data
Battery Type Lead-acid or Lithium Iron Phosphate Battery
Battery Voltage Range(V) 40-60
Max.Charging Current(A) 135 150 160 190 210 240
Max.Discharging Current(A) 135 150 160 190 210 240
Charging Strategy for Li-ion Battery BMS Adaptive
Number of Battery Input 1
PV String Input Data
Max. PV Access Power (W) 12000 14000 15000 16000 20000 24000
Max. PV Input Power (W) 9600 11200 12000 12800 16000 19200
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 160
MPPT Voltage Range (V) 200-650
Rated PV Input Voltage (V) 550
Max. Operating PV Input Current (A) 20+20 26+26
Max. Input Short-Circuit Current (A) 30+30 40+40
No. of MPPT Trackers/No. of Strings MPPT Tracker 2/1+1 2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W) 6000 7000 7500 8000 10000 12000
Max. AC Input/Output Apparent Power (VA) 6600 7700 8250 8800 11000 13200
Rated AC Input/Output Current (A) 9.1/8.7 10.6/10.1 11.4/10.8 12.2/11.6 15.2/14.5 18.2/17.4
Max.AC Input/Output Current (A) 10/9.6 11.7/11.1 12.5/11.9 13.4/12.8 16.7/16 18/19.2
Max.Continuous AC Bypass(Grid to load) (A) 63
Peak Power (Off-grid) (W) 2 Times Of Rated Power, 10s
Power Factor Adjustment Range 0.8 leading-0.8 lagging
Rated Input/Output Voltage/Range (V) 120/208 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (Rated power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Tracking Efficiency 99%
Equipment Protection
Integrated Protection DC reverse polarity protection, DC component monitoring, DC switch, AC output overcurrent protection, AC output overvoltage protection, AC output short-circuit protection, AC input overvoltage protection, AC input undervoltage protection, leakage current protection, thermal protection, anti-islanding protection, AFCI, GFCI, RSD compatible
Surge Protection Level DC Type II / AC Type III
Interface
Communication Interface RS485/CAN
Monitor Mode WIFI/Bluetooth/4G
General
Operating Temperature Range -40-60℃ (>45℃ Derating)
Humidity Range 0-100% RH (Non-condensing)
Operating Altitude(m) <2000
Noise Level @ 1m ≤55dB @ 25℃ (77°F)
Ingress Protection(IP)Rating IP66
Inverter Topology Non-Isolated
Dimensions(H×W×D) (mm) 638×383×230
Weight(kg) 58
Type of Cooling Natural cooling
Warranty 5 Years/ 10 Years
Certification
Overview UL1741, IEEE 1547