Max efficiency reaches 97.8%
TYPE 4X protection,adaptable for placement in
complex environments
Built-in integrated protection and rapid shutdown device
Supports string detection and monitoring,
and night time power supply function
|
Model |
KE-3K6E51UA |
KE-5KE51UA |
KE-6KE51UA |
KE-7K6E51UA |
KE-10KE51UA |
|
DC Input |
|
||||
|
Max Input Voltage |
600V |
||||
|
Rated Voltage |
330V |
||||
|
Start-up Voltage |
120V |
||||
|
Mppt Voltage Range mppt |
90 – 520V |
||||
|
Max Input Current |
14A/14A |
14A/14A/14A |
4×14A |
||
|
Max Short Circuit Current |
22A/22A |
22A/22A/22A |
4×22A |
||
|
Mppt Number/Max Input Strings Number |
2/2 |
3/3 |
4/4 |
||
|
AC Output |
|
||||
|
Rated Output Power |
3.6kW |
5kW |
6kW |
7.6kW |
10kW |
|
Max Apparent Output Power |
3.6kVA |
5kVA |
6kVA |
7.6kVA |
10kVA |
|
Max Output Power |
3.6kW |
5kW |
6kW |
7.6kW |
10kW |
|
Rated Grid Voltage |
1Ø/PE, 240/208 |
||||
|
Rated Grid Frequency |
50/60Hz |
||||
|
Max Output Current For 240v Grid |
15A |
20.8A |
25A |
31.7A |
41.7A |
|
Max Output Current For 208v Grid |
17.3A |
24A |
28.8A |
36.5A |
43.3A |
|
Power Factor |
>0.99 (0.8 Leading – 0.8 Lagging) |
||||
|
Thdi |
<0.3% |
||||
|
Efficiency |
|
||||
|
Max Efficiency |
97.3% |
97.7% |
97.8% |
||
|
CEC Efficiency |
96.6% |
97.1% |
97.5% |
||
|
Protection |
|
||||
|
DC Reverse-polarity Protection |
Yes |
||||
|
Ground Fault Monitoring |
Yes |
||||
|
Islanding Protection |
Yes |
||||
|
Integrated AFCI |
Yes |
||||
|
Integrated DC Switch |
Yes |
||||
|
Multi-peak Scan |
Yes |
||||
|
Rapid Shutdown |
Built-In APS or Tigo FSD |
||||
|
Surge Protection |
DC Type III/AC Type III |
||||
|
General Data |
|
||||
|
Dimensions (H×W×D) |
810×355×165mm |
732×335×249mm |
|||
|
Weight |
15.2kg |
21kg |
21.2kg |
||
|
Topology |
Transformerless |
||||
|
Self-consumption (Night) |
<1W |
||||
|
Relative Humidity |
0 – 100% |
||||
|
Operating Ambient Temperature Range |
-13°F to 140°F (-25°C to 60°C) |
||||
|
Storage Environment |
-13°F to 176°F (-25°C to 80°C) |
||||
|
Ingress Protection |
TYPE 4X |
||||
|
Noise (Typical) |
<30dB(A) |
||||
|
Cooling Method |
Natural Cooling |
Intelligent Air Cooling |
|||
|
Max Operation Altitude |
13,120ft (4000m) |
||||
|
Compliance |
UL1741SB, IEEE 1547 – 2018, UL1699B, UL1998, FCC Part 15 Class B, California Rule 21, HECO Rule 14H, NEC 690.12 – 2020, CAN/CSA C22.2107.1 – 1 |
||||
|
Caraterísticas |
|
||||
|
DC Connection |
1 knockout for 3/4″ conduit at bottom, side and back, Screw clamp terminal |
||||
|
AC Connection |
1 knockout for 3/4″ conduit at bottom, side and back, OT terminal |
||||
|
Display |
LCD |
||||
|
Communication |
RS 485, Optional: Cellular, Wi-Fi |
||||
© 2025 Ktech Energy Co., Ltd. Todos os direitos reservados. Política de privacidade