KE-N Series

Hybrid Inverter 5-12kW Three Phase European Grid

KE-5K/6K/7K5/8K/10K/12KD5L3EN

Features

Features
  • 01

    Enhanced insulation resistance testing technology

  • 02

    Compatible with Virtual Power Plant (VPP) Technology

  • 03

    Support higher charge-discharge current

  • 04

    Support diesel generator connection

  • 05

    MPPT tracking efficiency up to 99%

  • 06

    Easy installation

  • 07

    Equipped with comprehensive safety protection from software to hardware

Model KE-5KD5L3EN KE-6KD5L3EN KE-7K5D5L3EN KE-8KD5L3EN KE-10KD5L3EN KE-12KD5L3EN
PV Input Data
Max. PV Input Power (W) 10000 12000 14000 16000 20000 24000
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 150
MPPT Voltage Range (V) 180-650
Rated PV Input Voltage (V) 550
Max. Operating PV Input Current (A) 17+17 26+26
Max. Input Short-Circuit Current (A) 28+28 40+40
Number of MPPT Trackers 1+1 2 2+2
Max. Number of Input Strings 1+1 2 2+2
Battery Parameters
Battery Type Lead-acid or Lithium Iron Phosphate Battery
Rated Battery Voltage (V) 40-60
Max. Charge/Discharge Current (A) 125 150 180 200 220 250
Parallel Operation Mode
Max. Number of Parallel Units (pcs) 10
AC Input/Output
Rated Input/Output Active Power (W) 5000 6000 7500 8000 11000 12000
Rated Input Apparent Power (VA) 5500 6600 8250 8800 12100 13200
Rated Input/Output Current (A) 7.6/7.3 9.1/8.7 11.4/10.9 12.2/11.6 15.2/14.5 18.2/17.4
Max. Input/Output Current (A) 8.4/8 10/9.6 12.5/12 13.4/12.8 16.7/16 20/19.2
Peak Power (Off-Grid) 2 Times Of Rated Power, 10s
Power Factor Adjustment Range 0.8 leading – 0.8 lagging
Rated Voltage (V) 220/380, 230/400
Frequency (Hz) 50 (45-55) / 60 (55-65)
Connection Type 3L/N/PE
Total Current Harmonic Distortion (THDi) <3%(Rated power)
DC Current Output <0.5% x Rated current
Transfer Time (Bypass to Inverter) (ms) 10
Efficiency
Max. Efficiency 97.8%
Euro Efficiency 97%
MPPT Tracking Efficiency 99%
Device Protection
Integrated Protection DC/Battery Reverse Polarity Protection, DC/AC Lightning Protection, AC Overcurrent/Short-Circuit Protection Insulation Impedance Monitoring, Ground Fault Monitoring, Grid Monitoring, String Monitoring, Anti-Islanding Protection
Surge Protection Level DC Type II / AC Type III
General
Ingress Protection (IP) Rating IP66
Operating Temperature Range -40-60 ℃ (>45℃ Derating)
Humidity Range 0-100% RH (Non-condensing)
Noise Level @ 1m <45dB @ 25℃ (77°F)
Type of Cooling Natural cooling
Communication Port RS485/CAN; Option 1: WiFi + Bluetooth, Option 2: 4G + Bluetooth
Dimensions(H×W×D) (mm) 638x363x230
Weight (kg) 58
Operating Altitude (m) <2000
Warranty 5 Years /10 Years
Certification
Grid-Tie Standards IEC 61727, IEC 62116, CEI 0-21, EN 50549, VDE 0126-1-1, RD 1690, UNE 217002, RIVE-Netzlinie R25, GP99, VDE-AR-N 4105
Safety / EMC Standards IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Related Products

contact us

*We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.