Kayis Series

KE-7KD5LSUN

Split-Phase Hybrid Inverter For North Americas Grid

Features

Features
  • 01

    Integrated Disconnecting Switch

  • 06

    IP66 protection degree

  • 02

    Enhanced insulation resistance testing technology

  • 07

    UC Certified to UL1741, Rule 21, UL991, and UL1998 Standards

  • 03

    Compatible with Virtual Power Plant (VPP) Technology

  • 08

    AFCI & RSD

  • 04

    Grid-connected and off-grid operation; Support parallel connection of multiple batteries

  • 09

    Maximum Bypass Load Capacity: 200 A (Optional)

  • 05

    Support deep customization

Model KE-5KD5LSUN KE-6KD5LSUN KE-7KD5LSUN KE-7KD5DSUN KE-8KD5LSUN KE-10KD5LSUN KE-12KD5LSUN
Parallel Mode
No. of Parallel Machines Allowed (Unit) 10
AC Input/Output Data
Rated AC Input/Output Active Power (W) 5000 6000 7000 7500 8000 10000 12000
Max. AC Input/Output Apparent Power (VA) 5500 6600 7700 8250 8800 11000 13200
Rated AC Input/Output Current (A) 20.8 25 29.2 31.25 33.3 41.7 50
Max. AC Input/Output Current (A) 22.9 27.5 32.1 34.4 36.7 45.8 55
Max. Continuous AC Passthrough (grid to load) (A) 50 63
Peak Power (off-grid) 2 Times Of Rated Power, 10s
Power Factor Adjustment Range 0.9-1
Rated Input/Output Voltage/Range (V) 100~130/200~260 0.88Un<U<1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 2L+N+PE
Total Current Harmonic Distortion THDi <3%(Rated power)
DC Current Output <0.5% X Rated current
Conversion Time (bypass and inverter) 10ms
Battery Input Data
Battery Type Lead-acid / Lithium Iron Phosphate Battery
Max.Charging Current(A) 135 190 200
Max.Discharging Current(A) 135 190 200
Battery Voltage Range(V) 40-60
Charging Strategy for Li-ion Battery BMS adaptivity
Number of Battery Input 1
PV String Input Data
No. of Circuits 2/1+1 2/2+2
Max. PV Open-circuit Voltage (V) 550
Start-up Voltage (V) 100
Rated PV Voltage (V) 370
MPPT Voltage Range (V) 125-425
Max. PV Input Power (W) 7500 9000 10500 11250 12000 15000 18000
Max. Operating PV Input Current (A) 17+17 26+26
Max. Input Short-Circuit Current (A) 28+28 44+44
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 96.50%
MPPT Efficiency >99%
Equipment Protection
Integrated DC polarity reverse connection protection, AC output overload protection, thermal protection, AC output overvoltage protection, AC output short circuit protection, DC component monitoring, overvoltage load drop protection, ground current monitoring, arc fault circuit interruption(optional), grid monitoring, island monitoring, ground fault monitoring, DC input switch, DC terminal impedance monitoring, residual current monitoring (RCD), surge protection
Grid / Generator Circuit Breaker (Current / Voltage) 63A/480V
Load Circuit Breaker (Current / Voltage) 63A/480V
Battery Circuit Breaker (Current / Voltage) 250A/80V
General Data
Ingress Protection (IP) Rating IP66/TYPE4X
Operating Temperature Range(°C) -40~+60, >45℃ Derating
Permissible Ambient Humidity 0-100%
Noise Level @ 1m <30dB @ 25℃ (77°F)
Type of Cooling Intelligent Air Cooling
Communication Port RS485/RS232/CAN/WI-FI/Bluetooth/4G
Dimensions(HxWxD) 638x363x230mm (Excluding Connectors and Brackets)
Weight 30kg
Permissible Altitude <2000m
Warranty 5 Years /10 Years
Over Voltage Category TYPE II(DC), TYPE II(AC)
Certification
Overview UL 1741 3nd Edition ( September 28, 2021), CSA-C22.2 No.107.1-16, UL991/UL1998, CEC Efficiency, FCC SDOC Part 15B